BLOWDOWN INSTRUCTIONS

Blowdown is an essential part of generator operation. It is the

best preventive maintenance you can give your generator and
will add years of life to the unit. Make sure that a blowdown
schedule is established and followed regularly.

In extremely hard water areas, blowdown may be necessary

once a day. In other areas, once each week may be sufficient. If
there is a particular problem which applies to your local water
condition, other than mineral content, take this into consideration
in determining what schedule is to be followed.
1. At the end of the working day turn the control switch to the

OFF position and close the watter supply valve.

2. If blowing down into a receptacle, allow the pressure to

decrease to 15-20 psi before opening the blowdown valve.

3. It is preferable to connect the blowdown valve directly into a

drainage system, if local codes permit. If this is allowed, the
generator can be discharged at operating pressure.

4. When discharge is complete and the generator is drained, close

the blowdown valve and open the water supply valve, allowing
the generator to fill to normal level.

5. Close wall-mounted safety switch.
6. If you have been supplied with a manual reset control (as

required in some states), the reset button on the control must be
pushed before generator will begin developing pressure.
CAUTION: Do not push reset until boiler has filled with water.

7. WARNING: The use of chemical cleaning compounds in

these generators voids the warranty, unless approved by the
manufacturer.

OPERATION

WIRING DIAGRAMS

Standard

1-3 kW, 120V

1 Ø

Diagram 1

1-3 kW, 208V-480V

1 Ø

1-3 kW, 208V-240V & 480V

3 Ø

Diagram 2

Diagram 3

Diagram 4

Diagram 6

Diagram 5

Diagram 7

Diagram 8

Diagram 9

6 kW, 208V-480V, 1 Ø

9 kW, 480V, 1 Ø

9 kW, 230V-277V, 1 Ø

12-15 kW, 480V, 1 Ø

C

C

9 kW, 208V-220V, 1 Ø

12 kW, 277V, 1 Ø

40-47A

C

C

FU1

FU2

12 kW, 208V-240V, 1 Ø
15 kW, 208V-277V, 1 Ø

48A

C

C

FU1

FU2

C

C

FU3

FU4

6-15 kW, 208V-240V, 3 Ø

15 kW, 208V, 3 Ø

40A

C

FU1

C

C

FU2

FU3

From Power Circuit, Separate Source, or Transformer

C

W

B

R

Control Circuit Diagram

KEY

For All Units with Contactors

Contactor

Normally Open
Thermostat Switch

Black Lead

Red Lead

White Lead

C

B

R

W

120V 1Ph