Installation instructions

For the installer

Safety instructions

-

According to the technical connection

conditions of the electricity board serving

your area, the appliance may only be

connected to the mains supply by an

approved electrical installer.

- in the fixed connection, a device allowing

the appliance to be isolated on all poles

from the mains supply with a contact open­

ing width of at least 3 mm must be provid­

ed. Suitable isolating devices are Cooker
Control Units.

- In respect of fire protection, the appliance

conforms to type Y (lEC 335-2-6). Only

appliances of this type may be installed

on one side of adjacent upright kitchen
housings or walls.

Access protection must be ensured by

installation.

The distance between the hob and vapour

extractor hood must be of the extent indi­
cated in the instaliation instructions of the

vapour extractor hood.

Electricai connection of appiiance

Local and national electrical regulations must
be observed.

All instructions given by the Electricity Board

must be followed carefully when connecting

the oven to the mains supply.
The appliance Is rated for 240 volts single

phase and must be permanently connected.

The hob must be installed in such a way that it

can be easily disconnected from the mains
supply before servicing, eg by an adjacent
cooker control unit.
Sufficient cable should be left to enable the

hob to be removed from the work surface

whilst still connected to the mains supply

(approximately 1.5 metres or 5 ft).

When pushing the hob into the cutout of the

furniture housing, make sure that the mains

cable is neither kinked nor trapped under the

appliance.

Warning - This appliance must be earthed!

Voitage and Current

Please ensure that the voltage and current

indicated on the rating plate agrees with the

voltage of your electricity supply.

220/240 volts (ie 220/240 V a.c.).

After installation there must be no access to

live parts.