SYSTEMS FEATURES AND BASIC OPERATION

Figure 2. Valve Connection Details

Hydraulic Valve

The hydraulic valve is mounted on the frame of the
Laser Grading Box. It is an electrically-actuated
double-acting, single-section valve. Hoses and
quick-couplers to attach it the tractor’s auxiliary
hydraulics are included with the hydraulic kit.

An electrical cable is also provided. One end of the
cable has a 3-pin connector for the valve. The other
is open and can be attached to the Control Panel of
the automatic control system as required. Refer to
Figure 2 for wiring details of the cable and conduc­
tor functions.

The valve accepts a 12 VDC proportional current
signal from the Control Panel.

If you require a proportional time or 24 volt valve,
contact ATI Corporation.

EQUIPMENT SET-UP

Skid Steer Grading Box

1. Provide power to the Control Panel from the

skid steer’s electrical system. Usually this
involves a direct hookup to the battery.

2. The Laser Grading Box should be positioned

on a level area for attaching to the skid steer.
Start the skid steer and drive up to the attach­
ment plate and secure per the manufacturer’s
directions. The Level Best quick-attach plate
is designed to be universal.

NOTE: If the skid steer’s pins do not fit securely

into the rectangular holes at the base of
the attachment plate, these holes can be

notched larger to accept the pins.

Figure 3. Components of the Automatic Control System on a Skid Steer

3

Advertising