Troubleshooting – ATI Technologies Lawn Mower User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TROUBLESHOOTING

SYMPTOM

POTENTIAL CAUSE

REMEDY

Laser Grading Box does not raise

Control Panel not turned on.

Apply power.

or lower.

No hydraulic flow to Laser Grad­

ing Box.

Ensure hydraulic control handle

of skid steer or tractor is in
correct position.

Ensure auxiliary hydraulics are

ON or in continuous flow
mode.

Cables not connected correctly.

Refer to the automatic control

system documentation.

Move directional valve spool

manually using the overrides
on the end of the directional
valve.

A

warning

be sure to stay clear of any
moving parts of the Laser
Grading box.

If the Laser Grading Box
moves, refer to Electrical
problems. If the Laser Grading
Box does not move, refer to
Hydraulic problems.

Electrical Problems

Refer to the automatic control

system documentation.

Hydraulic problems.

Confirm hydraulic flow through

the manifold and returning to
the power source through the
“T” hose.

Contact ATI Corporation for help

troubleshooting the hydraulic
manifold.

Laser Grading Box moves in

opposite direction.

Hydraulic flow reversed.

Confirm the pressure is going in

the “P” port.

Verify control handle is moving in

desired direction.

10