Aiphone TB-10M User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TB-SE

TB-10M single-master system with a door station

• The # terminals on the master station connect to

terminal 1 on each TB-SE sub. These numbers

become the sub's station number, numbered from
the top on each 10-button row.

* 2 parallel wires per TB-SE sub, nonpolarized.

Be sure to run each pair of wires directiy to

TB-M master.

E iine in each pair shouid not be connected at
any other point of cabie than E terminais on
TB-M, which can accomodate 2 ~ 3 TB-SE subs.

Master station

TB-10M

Door adaptor

TB-AD1

IF-DA

-1

- 2

Eh

12V

IN

AC15-16V

or DC18V

-10

12V OUT

12V

T

R

S

S

-►To: power supply
-►

Sub station

TB-SE

Any # terminal on TB-M or TB-G
add-on selector.

★ Do not connect any power source here.

Call extension
IER-2
(one per TB-M)

f

"

f

~|

>

The master can select the door station for audio monitoring at any time. The call
announce pretone is selectable.
Set the switch to ON position for pretone, removing the cover of front case.

■ Wiring distance

TB-M to TB-SE sub

Diameter

0.65mm

0.8mm

1.0mm

Distance

400m

600m

900m

AWG

22AWG

20AWG

18AWG

Distance

1,300'

2,000'

3,000'

TB-AD1 to audio door station

Diameter

0.65mm

0.8mm

1.0mm

Distance

150m

230m

360m

AWG

22AWG

20AWG

18AWG

Distance

500'

750'

1,200'

TB-M to TB-AD1

Diameter

0.65mm

0.8mm

1.0mm

Distance

65m

100m

150m

AWG

22AWG

20AWG

Distance

210'

330'

18AWG

495'

TB-AD1

can be muted by switching

to OFF.

• 5 -

Advertising
This manual is related to the following products: