■ Connecting a buzzer at a TB-SE sub

When called by TB-M master, buzzer is
activated and on TB-SE sub, call tone sounds
at reduced volume.
TAR-3 relay activates an AC-operated buzzer:
AC 240V, 0.3A. DC-operated buzzer must be
mechanical type: DC 24V, 1 .OA.

Do not use DC electronic buzzer.

Buzzer

MOUNTING

■ TB-(10,20)MwithTB-(20,40)G

Remove 2 screws on front panel, removing the cover on upper end and area/section plate. Lift off front

case holding sides at top. Disconnect the intercom by unplugging the connector.
Open a cable inlet hole (rubber part) on bottom of chassis. Pull in cable(s), and make wire terminations.

Use attached cable clamps(s) for neat and secured connection. Reconnect and mount front case to

chassis, attaching the cover and plate in place.

When wall-mounting, separate the front panel from chassis, as explained above. Install the chassis

upside down on the wall, onto a single-gang or two-gang box.

Desk-top mounting

Area / section plate

Wall-mounting

Lift off front case holding sides
at top.

★ TB-M master wall-mounts with TB-G (and TB-AD10) attached.

Decide the exact location of TB-M master, and use the following measurements to mount the add-on components.

TB-M master

TB-G add-on
selector

TB-AD10door

adaptor

Wall-mounting guide

Master

Attached

Guide A

Attached

Guide B

TB-10M

TB-20G

202.5, 8"

TB-AD10

150.0, 6"

TB-40G

277.5, 11"

TB-AD10

225.0, 9"

TB-AD10

202.5, 8"

TB-20M

TB-20G

240.0, 9-1/2" TB-AD10

150.0, 6"

TB-40G

315.0, 12-1/2' TB-AD10

225.0, 9"

TB-AD10

240.0, 9-1/2"