TROUBLESHOOTING AND REPAIR

29

Removal of Right Stay Screws

Removal of Control Panel Assembly

Removal of Left Stay Screws

G. Remove (2) screws from Control Panel

Assembly Right Stay.

H. Remove (2) screws from Control Panel

Assembly Left Stay.

I.

Disconnect the following connectors from the
control board:

(1) Wire Harness, Relay Board to Control

Board J201 (10-pin)

(2) Drain Tank Switch J103 (2-pin)

(3) Room Temperature Thermistor J101

(2-pin)

(4) Freeze Thermistor J102 (2-pin)

(5) High Pressure Switch J104 (2-Pin)

NOTE: Mark each of the 2-pin connectors with a
different color marker to ensure the correct orienta-
tion when they are re-connected.