2.2.1 Wiring Detail – Auxiliary Cabinets

16 VAC

PWR

INPUT

1820 Telephone Intercom System
Wiring Detail - Auxiliary Cabinets

1

2

2

3

3

To additional Line Interface Boards

From Preceding Line Interface Boards

4

4

Power Supply Board can power up to 21 additional Line Interface Boards. The power supply board is
only need if over 21 Line Interface Boards are used, or if they are located over 200 feet from the main
control babinet.

DOORKING, INC., INGLEWOOD, CA 90301

Title:

Date:

Rev.

Dwg. No.

A

1820 Telephone Intercom System
Wiring Detail Auxiliary Cabinets

4/05

M1820-065-7

16 Volt, 50 VA UL Listed Transformer.