Page 25 – DoorKing 1820 User Manual

Page 25

Advertising
background image

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

1820 Telephone Intercom System
Wiring Detail for Dual RJ-71C Option

Rev.

Title:

4/05

A

M1820-065-9

17

21

15

14

13

20

19

18

11 12

16

23 24

22

1820 Telephone Intercom System
Wiring Detail - Dual RJ-71C Option

C.O.
PHN

16 VAC

PWR

INPUT

7

8

3

1

2

5

Lobby Panel

4

3

1 2

2

Earth Ground.

3

Optional Central Office phone line - touch tone, loop start.

4

Doorman / Concierge Telephone (Optional).

5

Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for
additional wiring requirements.

6

Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.

7

8

RJ71C phone block. See drawing M1816-065-6 for detail.

9

Incoming phone lines from Central Office.

10

Outgoing phone lines to individual apartments.

11

DoorKing connecting cable.

12

RS-485 connecting cable.

13

To additional Line Interface Boards.

Decoder board terminals. Used with 1816 systems only.

13

12

12

13

12 VDC

Reg

Input

14

14

Powered RJ-71C phone block P/N 1820-047 for use only with residents
without active Central Office phone service.

15

15

12 VDC Regulated power supply.

Resident
Telephone
without
C.O. Line

11

10

INCOMING

C.O. PHN

LINES

9

16

16

Disconnect the resident’s line form the phone company. Connect from
powered RJ-71C to resident’s terminals.

16 Volt, 50 VA UL Listed Transformer.

1

Doorman Telephone

4

6

6

1820-065-B-2-06

Page

25

Advertising