3.8.3 Set Direct Connect Disable Timer

If Doorman disable is allowed and the disable timer is On (see 3.8.2), then this programming step will
set the amount of time for the disable timer. When the timer expires, Direct Connect is restored. The
disable timer can be set from 1 (01) to 99 (99) minutes.

Factory Default = 30 (30 minutes)

1. Take the doorman telephone off hook.

2. Press *35 and enter the four-digit MASTER CODE _ _ _ _ (beep).

3. Enter a two-digit disable time (in minutes) _ _ , then press * (beep).

4. Hang up the doorman telephone to end the programming session.

3.8.4 Set Direct Connect Call-Down Number

This programming step sets the 1-digit number that the resident will use to call down to the Doorman /
Concierge telephone. The call-down number can be set from 0 – 9. Do not duplicate the 1-digit
resident programming number (see 3.8.5).

Factory Default = 7

1. Take the doorman telephone off hook.

2. Press *37 and enter the four-digit MASTER CODE _ _ _ _ (beep).

3. Enter the one-digit Direct Connect number _ then press * (beep).

4. Hang up the doorman telephone to end the programming session.

3.8.5 Set Resident Programming Number

This programming step sets the 1-digit number that the resident will use to enter a programming
mode to set various functions. The programming number can be set from 0 – 9. Do not duplicate the
1-digit resident Direct Connect number (see 3.8.4).

Factory Default = 8

1. Take the doorman telephone off hook.

2. Press *38 and enter the four-digit MASTER CODE _ _ _ _ (beep).

3. Enter the one-digit Direct Connect number _ then press * (beep).

4. Hang up the doorman telephone to end the programming session.