3 monitoring the system, 4 alarms, Monitoring the system – ADLINK PXIS-3320 User Manual

Page 24: Alarms

Advertising
background image

16

Installation

3.3 Monitoring the System

Light Emitting Diodes (LEDs) on the front panel tell you the power
status, chassis temperature, and fan operations. Refer to Table 3-
1
for details.

3.4 Alarms

The chassis comes with an alarm buzzer and an alarm reset but-
ton. The alarm buzzer beeps to alert you of any power, tempera-
ture, or fan failure. The alarm reset button resets the alarm monitor
system and stops the buzzer.

LED

Function

Color

Status

Indication

Power

DC rail voltages
(+3.3 V, +5 V,
+12 V, -12 V)

Green

ON

Power is supplied to
the system

OFF

No power is supplied to
the system

Temperature

Internal temperature
status

Red

ON

Internal temperature is
less than 50ºC

Flashing

internal temperature is
more than 50ºC

Fan

Fan speeds and
operation

Amber

ON

Fan speed is normal

Flashing

Fan speed is abnormal;
fan is defective

Table 3-1: LED indications