70

IPMI User Guide

OemRescanGaInput

This command is used to rescan the geo-address input pins and
reset the IPMB address according to the input value.

OemTestFunction

Internal test purposes only.

OemSetBlueLEDLongBlinking

This command is used to enable or disable the slow blink of the
blue HotSwap LED when a voltage is detected to be over ±5% out
of range for five seconds (see Table 4-1 on page 22).

This function

is set to enabled by default.

Action

Byte

Value

Description

Request

0

C0h

NetFn/LUN for OEM

1

22h

OEM defined command

Response

0

Complete Code

00h means OK

1

New IPMB address

New IPMB address value

Action

Byte

Value

Description

Request

0

C0h

NetFn/LUN for OEM

1

31h

OEM defined command

2

00h or 01h

00h: disable slow blink capability

01h: enable slow blink capability

Response

0

Complete Code

00h means OK

Advertising