Environmental specifications, Table 3, System power requirements (littleboard 800) – ADLINK RuffSystem 800 User Manual

Page 8: Table 4, Environmental requirements

Advertising
background image

RuffSystem Setup

4

User’s Guide

RuffSystem

Table 3

lists the current draw values of the RuffSystem with the LittleBoard 800.

Operating configurations:

In-rush operating configuration includes one LittleBoard 800, 1GB DDR RAM, AMI BIOS, I/O board,
AC/DC external digital power supply, DC/DC internal power module, CRT monitor, HDD, keyboard

and mouse.

Idle operating configuration includes the same items as the In-rush configuration.

BIT* = Burn-In-Test. Operating configuration includes Idle configuration as well as four serial loop
backs, one parallel port with loop back, two Ethernet connections, four external USB flash drives, and
one Compact Flash card.

Environmental Specifications

Table 4

provides the most efficient operating and storage condition ranges required for this system with the

LittleBoard 735, LittleBoard 800, and COM 840.

Table 3. System Power Requirements (LittleBoard 800, 1.4 GHz Pentium M CPU)

Input Type

In-rush Current
(@ 170.88W Power)

Typical Idle Current
(@ 9.54W Power)

Typical BIT* Current
(@ 13.18W Power)

+14VDC

12.21A

0.68A

0.94A

+16VDC

10.68A

0.60A

0.82A

+18VDC

9.49A

0.53A

0.73A

+20VDC

8.54A

0.48A

0.66A

+22VDC

7.77A

0.43A

0.60A

+24VDC

7.12A

0.40A

0.55A

+26VDC

6.57A

0.37A

0.51A

+28VDC

6.10A

0.34A

0.47A

+30VDC

5.70A

0.32A

0.44A

+32VDC

5.34A

0.30A

0.41A

NOTE

Extended temperature range available only on extended temperature tested
(ETT) systems.

Table 4. Environmental Requirements

Temperature

Humidity

Operating

Storage

Extended

Operating

Non-operating

-20

° to +65°C

(-4

° to +149°F)

–55° to +85°C
(–67° to +185°F)

–40° to +75°C
(–40° to +167°F)

5% to 90%
relative humidity,
non-condensing

5% to 95%
relative humidity,
non-condensing

Advertising