Technical data, Important information, Required safety distances – Austroflamm G1 User Manual

Page 6: Minimum distances – see name plate - in fig. 2), Setting up your stove

Advertising
background image

G1

4

english

1. TECHNICAL DATA


As a stove of construction type 1, it is possible to con-
nect it to the chimney of an existing other stove or an-
other hearth for solid fuels, as long as the chimney di-
mensioning complies with DIN 4705, Part 3.

TECHNICAL DATA

Height

677 mm

Width

400 mm

Depth

595 mm

Weight

85 kg

Flue pipe outlet diameter

120 mm

Nominal heat output (EN 13240)

6 kW

Maximum heat capacity

8 kW

Smallest heat capacity

3 kW

Room heating capacity
(depending on building insulation)

48-124 m³

Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the cal-
culation of the chimney measurements in accord-
ance with DIN 4705, Part 2
Fluegas mass flow

closed

5,2 g/s

Fluegas temperature

closed

330 °C

Minimum feed pressure

Nominal thermal output

closed

12 Pa

at 0.8 times
n. ther. outp.

10 Pa

2. IMPORTANT INFORMATION


The installation and operation information given here is
of general nature. National and European standards,
local and building regulations as well as fire prevention
laws must be observed during the operation of the
stove.

General safety instructions for the
operation of your stove


Thoroughly read the entire manual before starting up

your stove and observe the caution notices.

Your heating unit may not be moved without ap-

proved means of transport with sufficient load-bearing ca-
pacity.

Your heating unit is not suitable to be used as a stand

or as a ladder.

Please keep in mind that your

stove’s surface heats up considerably
during operation. We therefore rec-
ommend wearing a safety mitten
when operating your stove.

• Attention – stove varnish is no rust prevention!

Make your children aware of this particular danger

and keep them at a distance from the heating unit when-
ever it is in operation.

Only burn approved fuels and materials listed in the

chapter “Clean Burning”.

The burning or placing of flammable or explosive ma-

terials, like empty spray cans and such like into the firebox
as well as the storage of such materials in the immediate
vicinity of your heating unit is strictly forbidden due the
danger of explosion.

Do not wear loose or flammable clothing when adding

fuel to the fire.

Placing non-heat-resistant objects on the heating unit

or in the vicinity of the heating unit is forbidden.

Do not lay laundry onto the stove for drying. Laundry

hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.

The woodstove G1 is not suitable for long term heat-

ing.

During the operation of your heating unit it is forbid-

den to use flammable or explosive materials in the same
or an adjacent room to the one in which your heating unit
is located

.

The appliance must be operated with the stove door

closed.

The stove door and all fittings for adjusting the stove

must be closed, if the appliance is out of use.

Setting up your stove

Required safety distances

(Minimum distances – see name plate - in Fig. 2)

with protection shield or convection cladding

a > 800 mm b > 700 mm c > 400 mm

without protection shield or convection cladding

:

a > 800 mm b > 300 mm c > 300 mm
(a – toward the front in the radiated area)
(b – to the side)

(c – to the back)


Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly ad-
jacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the
stove

.


S