OPERATING THE REFRIGERATOR

Putting in operation

The cooling unit is silent in operation.
When the appliance is first put into operation, there may be a mild odour

which will disappear after a few hours. Ensure the living area is well ventilated.

The refrigerator will take several hours to reach its operating temperature

in the cooling compartment. The freezer compartment should be cold about
one hour after switching on the refrigerator.

Controls

6.1

6.1.1

Energy selection and temperature setting, “Piezo” igniter

A = energy selection switch
B = gas/electric thermostat
C = push button “manual ignition (Piezo-igniter

)”

D = flame indicator display (galvanometer)

Off

AC, mains power

Off

Gas

Note:

The refrigerator is equipped to operate on mains power or liquid gas (propane/butane).
The desired power option is selected by means of energy selector switch (A).
Energy selector switch (A) has four settings:
O (off1), 230V (mains power, AC) , O (off2), Gas (liquid gas)