Bonaire H2 Optimiser User Manual

Page 2

Advertising
background image

I

NSTALLATION

/

M

AINTENANCE

I

NSTRUCTIONS

H

2

Optimiser


Introduction

Your new Bonaire Integra has been fitted with an H

2

Optimiser water

management system. This H

2

Optimiser is designed to give increased water

savings through controlled management of the maintenance water.

All units using conventional bleed and dumping systems require regular

bleeding or dumping of the water during each day. With the H

2

Optimiser

Water Management system, water can be held for much longer periods of

time before being released conserving up to 45% of water usage.

This is achieved by using the CARE-FREE Water Conditioner A/C 6 in the

water distribution circuit. The CARE-FREE Water Conditioner A/C 6 disrupts

the cohesion of dissolved solids reducing the opportunity for scale

precipitation.

The H

2

Optimiser will only operate successfully when dissolved solids in the

water does not exceed 300 parts per million.

Set Up

Very little is required to set up the H

2

Optimiser. 2 dip switches in the control

box set the water drain cycle times suitable to the dissolved solids in the

water. The unit comes from the factory with the water drain cycle times preset.

The drain cycle dip switches are located inside the unit control box.

To check the correct setting has been applied, see the table below.

NOTE: Isolate the power to the control box before opening the control

box lid.

Maximum Pump Runtime Between Drain Cycles.

Dip Switches

100ppm

200ppm

300pm

Large

28hrs

23 hrs

16 hrs

Medium

33hrs

27 hrs

18 hrs

Small

48hrs

40 hrs

27 hrs