PROBLEM SOLVING

PROBLEM

PROBABLE CAUSE

REMEDY

a

Black – out

a

Wait

b

Tripped Circuit Breaker

b

Reset

c

Blown Fuse

c

Replace

Unit fails to start

d

Electrical Fault

d

Call Bonaire Service
Agent

a

Pump Seized

a

Isolate power and then
take off top of pump and
try to free it. Some
lubricant may help.

Pump fails to
start

b

Pump Burnt Out

b

Call Bonaire Service
Agent

a

Float Valve Leaking

a

Check adjustment or
replace seal

Water leaking
from overflow

b

Drain from Celdek Pads

b

Normal Operation

a

Loose Delivery Tube

a

Check and tighten

b

Break in tubing

b

Replace as necessary

Water Droplets
in air stream

c

Pump Delivers Excessive
Water to Pads

c

Adjust the Dialflo to
reduce the flow

a

Inadequate Exhaust

a

Provide more open area
to exhaust stale air

Excessive
humidity

b

Outside humidity high

b

Turn pump off.

a

Dirty Filters

a

Clean

b

Dry Filters

b

Check water delivery
system. Adjust if
necessary.

Inadequate
Cooling

c

Dialflo not set correctly

c

Adjust dialflo so that the
pads have even
saturation.

a

Unit located near odour
source

a

Remove source

Unpleasant
Odour

Rapid formation
of white
deposits on
pads

High Mineral Content

Bleed off should be set
at maximum. More
regular maintenance
may be required.

THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.