© 1999 Directed Electronics, Inc. Vista, CA

Sending a negative pulse to this wire will initiate the remote start sequence. This wire can be wired to an optional

momentary switch to activate the remote start system.

Connect this wire to the optional domelight supervision relay as shown below:

IMPORTANT! This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit because the output cannot support the current draw of one or more light bulbs.

Connect this wire to bare metal, preferably with a factory bolt rather than your own screw. (Screws tend to either

strip or loosen with time.) We recommend grounding all your components to the same point in the vehicle.

H1/8 BLACK (-) chassis ground connection

H1/4 BLACK /WHITE (-) 200 mA domelight supervision output

H1/3 WHITE/BLUE (-) activation input