Clay Paky A.LEDA WASH K20 User Manual

Page 22

Advertising
background image

22

A.LEDA WASH

TEST
Allows you to check the proper functioning of effects.
1) Press

F

to return to the top menu level.

2) Use the UP

B

and DOWN

C

keys to select the required test.

3) Press

F

to confirm the selection or LEFT

D

to keep current settings.

Test sequence:
Pan - Tilt effects (Pan & Tilt)
Colours
Zoom
All effects

To enable the "Advanced Menu" set up the "Access code" (1234) using the
UP

B

, DOWN

C

, RIGHT

E

keys.

Press

F

- "Menu advanced" appears on the display

POWER SUPPLY FAN 2 (only for A.leda Wash K20)
Lets you turn the PSU second cooling fan control on/off.

On: Fan on (as per last specifications).

Off: Fan off; the first A.leda Wash K20 lots (prior to projector with serial
number AC019438), were constructed with a single PSU cooling fan, a
firmware update could cause fault signals, disabling the fan, no error
will be displayed.

UP LOAD FIRMWARE
Allows you to transfer the firmware from 1 fixture to all the connected fixtures.
1) Press

F

, a confirmation message appears on the display.

2) Select YES to start the firmware loading or NO to keep the current

setting and return to the top menu level

SETUP MODEL
Allows you to change the default model of projector.
1) Press

F

a confirmation message appears on the display.

2) Select YES to define the model of projector or NO to keep the current

setting and return to the top menu level.

CALIBRATION
Allows you to adjust effects from the control panel to obtain perfect
uniformity between the projectors.
1) Press

F

- “channels” appears on the display.

2) Using the UP

B

and DOWN

C

keys, select the effect you wish to

regulate.

3) Press

F

and use the RIGHT

E

, UP

B

and DOWN

C

buttons to

make the adjustment by setting a value between 0 and 255.

4) Press

F

to confirm the selection or LEFT

D

to keep current settings

and return to the top level.

FACTORY DEFAULT
Allows you to restore default values of all channels (128).
1) Press

F

– a confirmation message appears on the display (Reset

calibration to factory default ?).

2) Select YES to reset calibration to factory default or NO to keep the

current setting and return to the top menu level.

Advanced

Code

1234

Calibration

Upload

Aleda fw

Pwr.Sp.

Fan 2

Transfer the firmware on all
the connected fixtures ?
Are you sure ?
Yes/No

Setup

Model

Changing to a wrong model
may damage the fixture.
Are you sure ?
Yes/No

ADVANCED MENU

TEST MENU

Test

Pan-Tilt
Colour
Zoom
All

Advertising
This manual is related to the following products: