DIGITAL START ADDRESS SELECT

OPTION SELECT

DIGITAL INPUT LEDS

1

16

1

2

4

8

16

128

32

64

TEST

256

ON

1

2

4

3

6

5

7

8

10

9

DIGITAL INPUT

ANALOGUE INPUTS

0-10V

• Zero setting the working hours and number of times the lamp is switched on

To zero the hours of the lamp’s life (“Bulb hours”) and the number of times it is
switched on (“Bulb strikes”) which are stored in the DMX Receiver microprocessor,
proceed as follows:

1. Set the TEST microswitch (32) to the ON position.

2. Shift the option 1 microswitch (37) from ON to OFF (or from OFF to ON) and vice

versa 3 times within a time of 6 seconds. If the procedure has been carried out
correctly, the three signal control LEDs (30) will light up simultaneously, while the
display (29) will go completely blank. This situation lasts for approximately
5 seconds.

3. Return the TEST microswitch (32) to the OFF position.

34

35

36

34

• Changing the lamp
Open the re-lamping cover, loosen the
two side ring nuts (34) of the lamp to be
replaced and remove it from its
mountings (35).
Take the new lamp out of its package,
loosen the two side ring nuts (34) and
insert the lamp in its mountings (35).
Finally, screw on the ring nuts.

WARNING: Do not touch the lamp’s
bulb with bare hands. Should this
happen, clean the bulb with a cloth
soaked in alcohol and dry it with a
clean, dry cloth.

IMPORTANT: To distribute the beam of
light uniformly, the lamp needs to be
positioned with the protrusion (36) visible
on the bulb outside the optical axis
of the projector. For this purpose it is
recommended to turn the protrusion
towards the top cover (19).

32

29

37

30

39

38

38

39

1

2

1

2

• Replacing colour filters

Find the filter to be replaced, grip it between your fingers and push it towards the
movable point of anchorage (38) until the filter comes out of the fixed points of
anchorage (39). Bend the filter outwards and take it out. Insert the new filter into the
mobile point (38) and anchor it in the two fixed points (39).

Standard colour filters

Disc 1

Disc 2

Red:

080301/005

Yellow with hole: 080323/002

Magenta: 080301/023

Blue with hole:

080323/001

Violet:

080301/004

4 colours:

080324/001

Green:

080301/003

Yellow:

080301/002

Wood:

080301/022

Orange:

080301/007

Blue:

080301/001

Hot:

080301/020

Pink:

080301/006

Cold:

080301/021

41

40

• Replacing metal gobos

Find the gobo to be replaced and delicately press towards the anchorage points (40)
until the gobo comes out.
Take the selected replacement from the holder (41) on the dimmer/stopper/strobe
plate.
To insert the new gobo, position it at the two points of anchorage (40) and, lightly pressing
it, slot it into the remaining points, verifying the levelness of the gobo in its housing.

STANDARD GOBOS - ROTATING GOBO WHEEL

082315/001

082311/005

081311/001

081319/001

STANDARD GOBOS - FIXED GOBO WHEEL

081329/001

081331/001

081330/001

081306/001

OPTIONAL GOBOS

081305/001

081313/001

081315/001

081316/001

081318/001

081321/001

081325/001

081307/001

081326/001

081327/001

MAINTENANCE

4

• Opening and closing the cover

Loosen the knob (33) and remove the re-lamping cover (19).
After maintenance refit the cover (19) and lock the knob (33).