Clay Paky MINISCAN User Manual

Miniscan, Instruction manual english

Advertising
background image

7

• Connecting the control signals

0-10V CONNECTION

- Projectors operating independently of one another

- Projectors operating simultaneously and identically

RS 232/423(PMX) - DMX 512 CONNECTION

Projectors are wired up to the controller and one to the next using two-core screened
cable and Cannon 5 pin XLR type plug/socket connectors.

• Connecting to the electrical power supply
The operations described in this heading must be carried out by a licensed elec-
trician.
The projector must be wired up to the electrical power supply using the special
socket connector provided. It is good policy to connect projectors to the power
supply by way of dedicated switches, so that each can be turned on and off indi-
vidually from a remote station.

The projector is designed to operate at the voltage and frequency indicated on the
electrical data plate (4) affixed to the rear end. Check that these two values corre-
spond to the mains voltage and frequency.

IMPORTANT: the projector must be connected to a power supply circuit having
a proper earth system (Class I appliance).

IMPORTANT: For better and more reliable operation of the projector, the ambient
temperature must not exceed 35° C (95° F). Protection factor IP 20: the appliance is
protected against penetration of solid bodies more than 12mm (0.5”) in diameter (first
digit 2), but can be damaged by spray, jet, drip or rain water (second digit 0).

DMX 512

RS 232/423

ENGLISH

0 - 10V

0 - 10V

0 - 10V

0 - 10V

8

Is

PAN

GOBO

COL

TILT

7

6

3

1

5

2

4

• Initial assembly operations
Position the bracket (2) the desired height and secure by tightening the knobs (3).
The bracket can also be fitted from the underside of the projector.

• Minimum distance from target objects
The projector must be positioned in such a way
that objects struck by the beam are separated
from the lens at least by the distance indicated on
the lamp change label next to the symbol illustrat-
ed alongside.

• Minimum distance of inflammable materials from any part of the equip-
ment:
0.10 m (4”).

The appliance may be mounted on surfaces rated normally inflammable.

• Fitting the lamp
Refer to directions for replacement of the lamp given under heading 6 MAINTENANCE.

• Installing the projector
The projector can be mounted in any position without its operating characteristics
being affected.

IMPORTANT: fix the projector in the desired position utilizing the holes in the brack-
et (2). Secure preferably using two ø10 bolts with nuts and lock washers.

Make certain that the anchorage is stable before positioning the projector.

INSTALLING THE PROJECTOR

1

POWER SUPPLY AND INTERFACE

2

• Unpacking
Open the box, remove the projector from the packing and place it on a flat hori-
zontal surface. Unpack the standard accessories supplied with the equipment.
Inspect the lamp change label (1) and replace with one of the optional language
versions if necessary.

Make certain that the label is never removed, as it displays important safety
information.

1

2

3

2

The connection between controller and projec-
tor must be made using a multicore cable with 8
wires of 0.25mm

2

section and a DIN 8 PIN 45°

plug/socket connector.

5

IMPORTANT: Read carefully. It is essential for the correct and safe use of the
equipment that erectors and operators should be fully conversant with the
information and instructions given in this manual.

INSTRUCTION MANUAL

ENGLISH

(

3’ 3”

)

1.0 m

HTI 300

HMD 300

HTI 150

(

1’ 8”

)

0.5 m

L

N

4

Mains

HMD 300
HTI 300
HTI 150

®

MINISCAN

Advertising