10

250 V

5A T

5 x 20

FUSE

• Changing the lamp (MINISCAN 300)
Open the projector, loosen the two side nuts (11) of the lamp to be changed and
remove it from the supports (12).
Remove the new lamp from its packaging, loosen the two side nuts (11) and locate
the lamp in the supports (12). Finally, retighten the nuts.

IMPORTANT: for uniform distribution of the light beam, the lamp must be positioned
so that the glass pip (13), on the bulb does not coincide with the optical axis of the
projector. With this in mind, locate the pip as high up as possible.

CAUTION: The projector uses a high pressure discharge lamp with
external starter.

• Routine cleaning

To maintain the light output of the projector undiminished, parts that tend to accu-
mulate dust and grease must be cleaned periodically.
In most circumstances, the projector will give long and trouble-free service if these
simple guidelines are followed.
To remove dirt from the lenses and filters, use a soft cloth moistened with any liquid
detergent suitable for cleaning glass.

IMPORTANT: do not use solvents or alcohol

Parts that need cleaning frequently.

Parts that need cleaning monthly.

Internal components should also be given a general clean once a year, dislodging
dust and dirt with a brush and removing it simultaneously with a vacuum cleaner.

• Replacing fuses

To change the fuses, press the tab (14) and
pull out the fuse holder (15). Replace any
blown fuse with one of the same type and rat-
ing as indicated on the label (16) attached to
the holder (15). Insert the fuse holder and
push in to engage the tab (14).

CAUTION:

- When fitting a new lamp, read the manufacturer’s instructions carefully.

- The lamp must always be changed without delay if damaged or deformed by heat.

14

15

16

TROUBLESHOOTING

7

No electrical power supply.

Check that power is available at the
mains socket and/or that fuses are
intact.

PROJECTOR DOES NOT LIGHT UP

ELECTRONICS NOT WORKING

FAULT

PROJECTION FAULTY FAULTS

REDUCED BRIGHTNESS

POSSIBLE CAUSES

CHECKS AND REMEDIES

Lamp expended or faulty.

Change lamp (see instructions).

Signal transmission cable short-cir-
cuiting or disconnected.

Change cables.

Address codes incorrect.

See projector coding instructions.

Defect in electronic circuits.

Contact an authorized technician.

Lenses broken.

Contact an authorized technician.

Deposit of dust or grease.

Clean (see instructions).

TECHNICAL DATA

8

11

12

13

11

ELECTRICAL/MECHANICAL
SPECIFICATION

Power supply

MINISCAN
220 - 240V 50Hz
200V 50Hz - 230V 60Hz
200V 60Hz

MINISCAN 300
Metal iodide type with special built-in
power supply unit.
Type HMD 300W

- Cap SFc 10-4
- Colour temperature 5000 K
- Luminous flux 18000 lm
- Average life 3000 h

Type HTI 300W

- Cap SFc 10-4
- Colour temperature 6500 K
- Luminous flux 22000 lm
- Average life 750 h

MINISCAN 150
Metal iodide type with special built-in
power supply unit.
Type HTI 150W

- Cap GY 9.5
- Colour temperature 6900 K
- Luminous flux 9500 lm
- Average life 750 h

Power consumption
MINISCAN 300: 800VA at 220V 50Hz
MINISCAN 150: 500VA at 230V 50Hz

Motors
N. 4 microstepping motors with full micro-
processor control.

OPTICAL SYSTEM

Optical unit
Main optical unit in diecast aluminium,
incorporating twin lens condenser and a
reflector of high luminous efficiency.

Lens units
Standard: 1:2,5/165 mm (9°).
Optional: 1:2,2/100 mm (15°20’).

MIRROR HEAD
Mirror of ultra high luminous efficiency.

Movement
Produced by two controlled microstep-

ping motors.

Infinitely variable speed of rotation;

maximum values:
- horizontal (PAN) = 0.4 sec (150°)
- vertical (TILT) = 0.3 sec (110°)

Continuous and uniform movement.

Resolution:
- PAN = ±0.3° (150°)
- TILT = ±0.2° (110°)

CONTROL SYSTEMS

Channels
N. 4 control channels.

Inputs
The MINISCAN is set up to accept analog
or digital signals from controllers or com-
puters.
Digital serial input: RS232/423(PMX) or

DMX 512

Analog input 0-10V

GENERAL CHARACTERISTICS

Safety devices
Power supply shuts off automatically in

the event of overheating or cooling sys-
tem failure.

Power shuts off automatically when cover

is opened (MINISCAN 300 only).

Cooling
Forced ventilation cooling system using
axial flow fans.

Housing
Extruded die-cast aluminium..
Epoxy powder coated finish.

Mounting
Steel bracket with epoxy powder coated

finish.

Two installation positions, 50 mm (2”) apart.
Bracket adjustable through 110°.

Operating position
Will function in any position.

Weights and dimensions
MINISCAN 300: 10.5 kg. (23 lbs 2 ozs)
MINISCAN 150: 8.5 kg. (18 lbs 11 ozs)

(9.4”)

238

(22.9”)

582

(11”)

280

Advertising