Clay Paky V.I.P. 250 ALO / ST User Manual

Page 4

Advertising
background image

8

TECHNICAL DATA

6

Power supply

• 24V 50/60Hz

Input power

• 260VA

Lamp

• Halogen 24V 250W

- Connection G6.35
- Colour temperature 3,450 K
- Luminous flux 9,000 lm
- Average life 300 h

Optical unit

• Base in die-cast aluminium.
• Twin lens condenser.
• Spherical reflector with a high

luminous efficiency.

Lens units

• Standard: 1:2,4/100 mm (30,9°)
• Optional: 1:2,8/45 mm multi-lens (64,2°)
• Optional: 1:2,8/60 mm multi-lens (45,8°)
• Optional: 1:2,8/85 mm multi-lens (34,4°)
• Optional: 1:2,8/120 mm multi-lens (24,1°)
• Optional: 1:3,5/150 mm multi-lens (19,5°)
• Optional: 1:4/165 mm (17,2°)
• Optional: 1:4,4/200 mm (14,3°)
• Optional: 1:3,5/70÷120 mm zoom

(39,5°÷22,9°)

Safety Devices

• Short-circuiting protection on the

accessory holder guides.

Cooling

Forced ventilation with an axial fan.

Body

• In die-cast and extruded aluminium.
• Epoxy powder painting.

Mounting

• Bracket in steel painted with epoxy

powders.

• Three installation positions with a step

of 25 mm (0.98”).

• Bracket adjustable on 120°.

Working position

Operation in any position.

Dimensions and weights

Weight: 2,2 kg (4 Ibs 13 ozs).

(14.13”)

359

(8.07”)

205

(8.86”) 225

(10.83”) 275

(5.12”)

130

(7.28”)

185

(6.69”)

170

TROUBLESHOOTING

5

No mains supply.

Check there is power at the
supply socket.

THE PROJECTOR WILL NOT SWITCH ON

NO MOTOR-DRIVEN ACCESSORY WORKS

TROUBLE

DEFECTIVE PROJECTION

REDUCED BRIGHTNESS

POSSIBLE CAUSES

CHECKS AND REMEDIES

Lamp exhausted or defective.

Replace the lamp.
(See instructions).

No power on the guides.

Call an authorized technician.

The accessory motors fail to
work.

Call an authorized technician.

Lenses or reflector broken.

Call an authorized technician.

Dust or grease deposited.

Clean. (See instructions).

Advertising