Communication Tasks 5.9

Communications

5-289

Example 1
In this spline segment, all points are equidistant along the X (time or geared) axis:

Assuming this segment is being downloaded to axis 0 on an RMC with just two spline-capable axes,
here is the register assignment:

Address

Register

Value

12288

I.T. Format

0 (equal intervals)

12289

Interval Table

– 0

T (interval between each point
pair)

14336

Point Count

5

14337

Point Table –

0

P0

14338

Point Table –

1

P1

14339

Point Table –

2

P2

14340

Point Table –

3

P3

14341

Point Table –

4

P4

Example 2
In this spline segment, the distance along the X (time or geared) axis between points varies:

Assuming this segment is being downloaded to axis 0 on an RMC with just two spline-capable axes,
here is the register assignment:

Address

Register

Value

12288

I.T. Format

1 (separate intervals)

12289

Interval Table

– 0

T0 (distance between P0 and P1)

12290

Interval Table

– 1

T1 (distance between P1 and P2)

12291

Interval Table

– 2

T2 (distance between P2 and P3)

12292

Interval Table

– 3

T3 (distance between P3 and P4)

14336

Point Count

5

14337

Point Table –

P0