OFFSET

+ 65535.

Example 3:

SCALE

: 32050

OFFSET

: 1000

Position Range: 1000 to 65535
Discussion: Because

SCALE

is positive, the positions range from

OFFSET

to

OFFSET

+ 65535. However, because the upper limit would be greater than 65535

(66535), it is truncated at 65535.

Example 4:

SCALE

: -30300

OFFSET

: 40000

Position Range: -25535 to 40000
Discussion: Because

SCALE

is negative, the positions range from

OFFSET

- 65535

to

OFFSET

.

Example 5:

SCALE

: -31541

OFFSET

: -10000

Position Range: -65536 to -10000
Discussion: Because

SCALE

is negative, the positions range from

OFFSET

- 65535

to

OFFSET

. However, because the lower limit would be less than -65536 (-75536),

it is truncated at -65536.

COMMAND POSITION

The COMMAND POSITION is the requested position (specified by the

COMMAND

VALUE

) with bounds checking applied. If the requested position is outside the

RETRACT

or

EXTEND LIMIT

, the COMMAND POSITION will be set to the value of

the limit, and the axis will go only to the limit. The COMMAND POSITION is updated

when any move command, or

'P' command

is issued using the COMMAND parameter.

Why Bother?

If the COMMAND POSITION is not the same as the requested position then one of two

things has happened:

1. A program error has asked the axis to go to an invalid position. In this case the

program error should be corrected. The PARAMETER ERROR bit in will be ON

when this occurs.

2. The

COMMAND VALUE

field has just been changed and the Motion Controller

has not had a chance to acknowledge the new request. Note that the IN POSITION

bit is no longer valid for the rest of the scan. The IN POSITION bit is valid only

when the

COMMAND VALUE

is equal to the COMMAND POSITION.