Programmable controller commands, Go using profile commands – Delta MMC120 User Manual

Page 87

Advertising
background image

87

Decimal: 121

Hexadecimal: 079

Command Value: Unused

This command begins a new graph immediately. A move can, but doesn’t have to, be in

progress.

Programmable Controller Commands

Go Using Profile Commands

Format: 0000 RRRR 0001 NNNN

R Used for

Status Area Request

N Used for Command Index described below

These commands allow the Programmable Controller to tell the motion controller to

move the axis using stored

profiles

. These are generally the most commonly used

commands. The Go Using Profile command operates identical to a standard

Go

command

except that the move uses the MODE, ACCEL, DECEL and SPEED fields

from the selected profile.
The format of the Command Register for the Go Using Profile commands is given below:

|

| 111|1111

BIT # 1234|5678|9012|3456

-------------------

HEX

|SAR |CMND|INDX

VALUE -------------------

0X10

0000|XXXX|0001|0000 GO USING PROFILE 0

0X11

0000|XXXX|0001|0001 GO USING PROFILE 1

0X12

0000|XXXX|0001|0010 GO USING PROFILE 2

0X13

0000|XXXX|0001|0011 GO USING PROFILE 3

0X14

0000|XXXX|0001|0100 GO USING PROFILE 4

0X15

0000|XXXX|0001|0101 GO USING PROFILE 5

0X16

0000|XXXX|0001|0110 GO USING PROFILE 6

0X17

0000|XXXX|0001|0111 GO USING PROFILE 7

0X18

0000|XXXX|0001|1000 GO USING PROFILE 8

0X19

0000|XXXX|0001|1001 GO USING PROFILE 9

0X1A

0000|XXXX|0001|1010 GO USING PROFILE 10

0X1B

0000|XXXX|0001|1011 GO USING PROFILE 11

0X1C

0000|XXXX|0001|1100 GO USING PROFILE 12

0X1D

0000|XXXX|0001|1101 GO USING PROFILE 13

0X1E

0000|XXXX|0001|1110 GO USING PROFILE 14

0X1F

0000|XXXX|0001|1111 GO USING PROFILE 15

Advertising