Calibrate tracker to beacon, Tk series guidance system operator’s manual – Ditch Witch TK Series Manual User Manual

Page 38

Advertising
background image

TK Series Guidance System Operator’s Manual

System Operation - 37

Setup

CMW

Calibrate Tracker to Beacon

Manual Method

TX and TXH beacons have one-way communication with the tracker. To accurately scale depth, calibrate
the tracker to the beacon.

1.

Activate beacon and place on ground exactly
10 ft (305 cm) from tracker, as shown.

2.

Position tracker parallel to center of beacon.

3.

Select Beacon>Calibrate Depth and follow
prompts.

Bluetooth Method

TXQ and TXQG beacons utilize Bluetooth radios
for two-way communication with the tracker. Once
the tracker is paired to the beacon, calibration
takes place automatically. To pair the tracker with
the beacon:

1.

Activate the beacon.

2.

On the tracker, go to Wireless>Bluetooth.
Select the correct TX_0000 beacon to create a connection.

3.

Select Beacon>Calibrate Depth and follow prompts. This step will calibrate both UP and DOWN
modes.

IMPORTANT: If using a multi-frequency
86 Series beacon or a multi-mode TX
series beacon, calibrate each frequency
separately.

e17om051w.eps