Finish locating, Log data, Tk series guidance system operator’s manual – Ditch Witch TK Series Manual User Manual

Page 45

Advertising
background image

System Operation - 44

TK Series Guidance System Operator’s Manual

Finish Locating

CMW

Finish Locating

When location is complete, remove beacon from tool housing before mud in beacon chamber hardens and
seizes beacon into housing.

1.

Remove beacon from tool housing.

2.

Clean beacon and remove battery.

3.

Wash and lubricate tool housing.

Log Data

Tracking data can be saved to a file on the tracker or the display and transferred directly to a personal
computer with TSR or TMS PLUS software.

1.

Select file to save data:

To create a new log file, navigate to Logging>New Log.

To add data to an existing log file, navigate to Logging>Log Manager.

Note: All data will be stored to the selected log file until another log file is selected or until logging is
disabled.

2.

Log data along bore path using Auto-Log or Manual log.

3.

When logging is complete, transfer data to a personal computer.

IMPORTANT: If beacon will not come out, do not use force. Try soaking housing in water until
dried mud inside housing softens. If beacon still will not come out, contact your Ditch Witch
dealer for advice.

TK

TD

Auto-Log

Pipe is logged when the Select/
Send
button is pressed to send
depth to display.

Pipe is logged when depth is received
from tracker. No user action is required.

Manual log

Pipe is logged after a depth has
been sent to the remote display and
the Up button is pressed while the
depth value is still highlighted.

Pipe is logged when depth has been
received from the tracker and the
Select/Send button is pressed.