As needed, Vacuum system, Fx30/fxt30 operator’s manual – Ditch Witch FXT30 User Manual

Page 110

Advertising
background image

FX30/FXT30 Operator’s Manual

Service - 109

As Needed

CMW

®

As Needed

Vacuum System

Change Water Pump Filter

1.

Open filter housing.

2.

Remove element and rinse housing
thoroughly with clean water.

3.

Install new element and close filter housing.

Lube Blower for Long-term Storage

Lubricate blower before long-term storage to help
prevent rust and siezing.

1.

Remove plug from fitting at filter.

2.

Start engine.

3.

Spray light oil into port and run unit for 1-2
minutes.

4.

Turn off engine.

Location

Task

Notes

VACUUM
SYSTEM

Change water pump filter

Lube blower for long-term storage

Change blower relief air filter

Empty cyclonic separator canister

DEBRIS
TANK

Clean primary shutoff valve

TRAILER

Add surge brake fluid

DOT 3 or 4

j33om047h.eps

j33om047h.eps