Debris tank, Fx30/fxt30 operator’s manual – Ditch Witch FXT30 User Manual

Page 112

Advertising
background image

FX30/FXT30 Operator’s Manual

Service - 111

As Needed

CMW

®

Debris Tank

Clean Primary Shut-off Valve

Clean primary shut-off valve as needed. Replace
primary shut-off valve as needed.

To clean:

1.

Open tank door. See “Open/Close Tank Door”
on page 73.

2.

Spray valve housing inside vacuum tank with
high-pressure water.

3.

Store water pressure hose.

4.

Close tank door. See “Open/Close Tank Door”
on page 73.

To remove:

1.

Loosen three wingnuts (1) and pull out valve housing (2).

2.

Remove ball (3).

3.

Clean ball and housing with high-pressure water.

4.

Replace ball and housing.

5.

Tighten wingnuts.