Locate - 27

Active Location

CMW

Induction Clamp

To set up transmitter for use with induction
clamp:

1.

Plug cable into transmitter (1).

2.

Place clamp around line (2).

3.

Turn on transmitter.

4.

Check battery level indicator.

Jobsite hazards could cause death or serious injury. Use

correct equipment and work methods. Use and maintain proper safety
equipment.

NOTICE: Electric shock or equipment damage can result if transmitter is connected to live cable.
Contact qualified utility personnel and follow all standards and requirements for disconnecting and
grounding lines.

NOTICE: Do not unplug induction
cable from transmitter (1) when
connected to line (2). Removing cable
will cause an arc and could damage
equipment or cause injury.