Caution, Two-man earth auger powerhead 9800 series, Troubleshooting guide – EarthQuake 9800B User Manual

Page 13

Advertising
background image

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

13

Operator's Manual

Two-Man Earth Auger Powerhead 9800 Series

CAUTION

PRACTICE SAFETY AT ALL TIMES. ENGINE MUST BE

TURNED OFF AND ALLOWED TO COOL, AND SPARK

PLUG WIRE MUST BE DISCONNECTED BEFORE

ATTEMPTING ANY MAINTENANCE OR REPAIR.

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

REMEDY/ACTION

Engine will not start

1. Power switch off

1. Flip switch to ON position

2. Spark plug wire disconnected

2. Connect spark plug wire to spark plug

3. Fuel valve closed

3. Open fuel valve

Engine runs rough, floods during

operation

1. Dirty air cleaner

1. Clean or replace air cleaner

2. Carburetor out of adjustment

2. Take to authorized Briggs & Stratton/Honda

service center

3. Fuel valve closed

3. Open fuel valve

Engine is hard to start

1. Stale fuel

1. Drain old fuel and replace with fresh. Use gas stabi-

lizer at end of season

2. Spark plug wire loose

2. Make sure spark wire is securely attached to spark

plug

3. Dirty carburetor

3. Clean carburetor, use gas stabilizer, new gas can

Engine misses or lacks power

1. Clogged fuel tank

1. Remove and clean

2. Clogged air cleaner

2. Clean or replace

3. Improper carburetor adjustment

3. Take to authorized Briggs & Stratton/Honda service

center

4. Spark plug dirty, improper gap, or wrong

type

4. Replace spark plug and adjust gap

Auger turns at idle

1. Idle speed too high

1. Adjust idle speed lower

2. Broken clutch spring

2. Replace both springs

Auger turns, but has no power

1. Carburetor out of adjustment

1. Take to authorized Briggs & Stratton/Honda service

center

2. Broken transmission

2. Replace transmission

3. Worn clutch shoes

3. Replace clutch

4. Worn engine lower seal

4. Take to authorized Briggs & Stratton / Honda ser-

vice center

Auger cuts slowly

1. Damaged point

1. Replace fishtail point

2. Worn out blade

2. Replace blade

Engine runs, then quits

1. Screen in carburetor plugged

1. Clean screen, use gas stabilizer, clean gas can

2. Fuel valve closed

2. Open fuel valve

NOTE: Please see the engine manual for any engine issues.

While normal care and routine maintenance will extend the life

of your auger powerhead, prolonged or constant use may even-

tually require that service be performed to allow it to continue

operating properly. The troubleshooting guide below lists the

most common problems, causes and remedies.

Advertising