Operator’s Manual

800 Watt Inverter Generator

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

16

IMPORTANT

NEVER TWIST AIR FILTERS WHEN CLEANING. ALWAYS PRESS.

CAUTION

ENGINE MUST BE TURNED OFF AND COOL BEFORE

CHECKING AND ADJUSTING ENGINE OR EQUIPMENT.
TEMPERATURE OF MUFFLER AND NEARBY AREAS

MAY EXCEED 150° F (65° C). AVOID THESE AREAS.
NEVER STORE ENGINE WITH FUEL IN THE TANK INSIDE

A BUILDING. POTENTIAL SPARKS MAY BE PRESENT

FOR IGNITION OF FUEL AND FUEL VAPORS.
AN ADULT ONLY MUST DO MAINTENANCE AND

REPAIR ON GENERATOR.
ENGINE MUST BE TURNED OFF AND COOL BEFORE

ANY REPAIR OR MAINTENANCE CAN BE DONE.
DO NOT OVER FILL THE ENGINE CRANKCASE WITH

OIL. HIGH OIL PRESSURE MAY RESULT, CAUSING

PREMATURE ENGINE WEAR AND DAMAGE.

STEPS FOR WORKING ON EQUIPMENT

1. Flip the engine switch to the STOP position.
2. Replace or repair the part on the IG800W.
3. Check all parts that were repaired, or removed during repair,

that they are secure and fit correctly.
NOTE: Only use approved Earthquake spare. Never replace

parts that are not specifically designed for the generator.

OIL MAINTENANCE

After the first twenty hours of operating a new Viper engine

the oil should be replaced, and every 100 hours of operating

time thereafter. The oil should be changed every 50 hours if

used under severe conditions, such as in high temperatures or
under heavy loads. Check oil periodically; do not overfill!

ENGINE OIL REPLACEMENT

1. Place the machine on a level surface and warm up the en-

gine for several minutes. Then stop the engine and turn the

fuel valve to the OFF position and the fuel tank cap air vent

to the CLOSED position.

2. Remove the side panel on the starter handle side of the gen-

erator by loosening the four screws holding it in place.

3. Remove the oil fill cap.
4. Place an oil pan under the engine. Tilt the generator to drain

the oil completely. Once oil has been removed return the

generator to the level surface.

5. Add engine oil, 10W-30 (API Service SJ, SL or better). Fill to

the upper level. For extreme high and low temperature con-

ditions refer to SAE chart. SEE FIGURE 7

6. Install the oil fill cap back in place.
7. Reconnect the side panel to the generator and tighten down

the four screws.

CAUTION

BE SURE NO FOREIGN MATERIAL ENTERS THE

CRANKCASE WHEN ADDING OR CHANGING OIL.
DO NOT TILT GENERATOR WHEN ADDING OIL. THIS

COULD RESULT IN OVERFILLING AND DAMAGE.
THE ENGINE SHOULD NEVER RUN WITHOUT THE AIR

FILTER; EXCESSIVE PISTON AND/OR CYLINDER WEAR

MAY RESULT.

CAUTION

TO AVOID INJURY OR DEATH, NEVER SIPHON FUEL BY

MOUTH.
NEVER STORE GENERATOR WITH FUEL IN THE FUEL

TANK INSIDE AN ENCLOSED AREA OR BUILDING.

10W-40

10W-30

5W-30

-20

0

20

40

60

80

100 °F

-30

-20

-10

0

10

20

30

40 °C

Environment Temperature

SAE

FIGURE 7