Monitoring & Control Example Application

You can use the Monitoring & Control Example Application to monitor a 3150

EVB running the MGDemo example application. You can also use this
application to monitor ISI messages from any devices on the same network. The

Monitoring & Control Example Application is a Windows application written in

Microsoft Visual C#. It requires Microsoft .NET Framework 1.1 to run. The
Microsoft .NET Framework is installed on your computer when you install the

Mini EVK software if you do not already have it. The Monitoring & Control

Example Application uses the OpenLDV API to monitor and control network
variable and ISI messages. The OpenLDV API is also installed on your computer

when you install the Mini EVK software if you do not already have it. The
Monitoring & Control example is installed in the L

ON

W

ORKS

MiniKit\Examples\Monitor & Control folder. This example works with any

evaluation boards on your network that have the MGDemo application loaded.

This section describes how to use the Monitoring & Control Example Application

to monitor a 3150 EVB and to monitor ISI messages. See Appendix B,

Monitoring & Control Application Overview, for information on how this example
is implemented.

To use the Monitoring & Control Application, follow these steps:

1. Load the MGDemo application into a 3150 EVB as described earlier in

this chapter.

2. Open the Echelon Mini EVK program folder and then select

Monitoring & Control Example Application. The window shown in

Figure 3.1 opens.

Figure 3.1 Network Interface Window

3. Select a network interface, and then click Connect. The window shown

in Figure 3.2 opens.

You can use the U10 or U20 USB Network Interface included with the

Mini EVK, or you can use another network interface such as a PCC-10,
PCLTA-20, PCLTA-21, i.LON 10 Ethernet Adaptor, or i.LON 100

Internet Server. If you are using the U10 or U20 USB Network Interface

included with the Mini EVK and do not have any other network
interfaces installed on your computer, select LON1.