5replacing a blown main fuse, Replacing remote control batteries, Input configurations – Electrocompaniet ECI 5 MKII User Manual

Page 5: Output configurations

Advertising
background image

5

Replacing a blown main fuse

(Diagram 5, page 15)

The main fuse is located in a small drawer inside the AC inlet of the unit.

If, for some reason the fuse is blown, turn the unit off, and remove the

AC cord from the AC inlet. Open the drawer with a small screwdriver

and remove the blown fuse. The spare fuse is located inside a holder in

front of the main fuse.

1. Remove the spare fuse gently by pushing it sideways out of its holder.

2. Insert the spare fuse as the active fuse.

3. Push the drawer gently back to closed position.

4. Re-insert the AC cord and turn the unit on.

Never replace the fuse with other values than indicated on the unit!

Replacing remote control batteries

(Diagram 4, page 15)

To replace the battery, lift the cover off, and insert a fresh set of batter-

ies. Be careful to follow the + and - polarity indications at the bottom of

the battery compartment.

Battery type: 2 x LR03 / AAA: 1.5Volts

Input configurations

(Diagram 6, page 15)

XLR input: 1 = ground 2 = positive 3 = negative

RCA: Center = positive Circle = ground.

Output configurations

(Diagram 6, 15 and 1, pg 14)

XLR output: 1 = ground 2 = positive 3 = negative

Speaker: Red = positive Black or White = ground

ECP5XLR:

RCA to XLR adapter: 1 & 3; ground and negative = shorted 2 = positive

ENG