Table 8. ACV Detailed Accuracy Specifications
Table 9. DCA Detailed Accuracy Specifications
Table 10. ACA Detailed Accuracy Specifications
Table 11. Resistance Detailed Accuracy Specifications
-34-
Range
Resolution
Accuracy
Note
400mV
0.1mV
±(1.5% rdg + 8)
Frequency Response:
50Hz - 400Hz
Input Resistance: 10M
Ω
Overload Protect: 400mV
range 250V rms. The rest
600VDC or 600VAC rms.
4V
1mV
±(0.8% rdg + 5)
40V
10mV
400V
100mV
600V
1V
±(1.2% rdg + 5)
Range
Resolution
Accuracy
Note
40
µA
0.1
µA
±(2.0% rdg + 5)
Overload Protect: Fast fuse
0.5A/250V and fast fuse
10A/250V.
10A for 15sec. maximum
Input Voltage Drop: <0.4V
400
µA
1
µA
40mA
10
µA
±(1.5% rdg + 5)
400mA
100
µA
4A
1mA
±(2.0% rdg + 5)
10A
10mA
Range
Resolution
Accuracy
Note
40
µA
0.1
µA
±(2.5% rdg + 3)
Overload Protect: Fast fuse
0.5A/250V and fast fuse
10A/250V.
10A for 15sec. maximum
Input Voltage Drop: <0.4V
Frequency Response:
50Hz - 400Hz
400
µA
1
µA
40mA
10
µA
±(2.0% rdg + 5)
400mA
100
µA
4A
1mA
±(2.5% rdg + 5)
10A
10mA
Range
Resolution
Accuracy
Note
400
Ω
100m
Ω
±(1.0% rdg + 5)
Overload Protect: 250V rms
4k
Ω
1
Ω
40k
Ω
10
Ω
400k
Ω
100
Ω
4M
Ω
1k
Ω
40M
Ω
10k
Ω
±(2.0% rdg + 5)