Elenco Digital Bench Multimeter User Manual

Page 16

Advertising
background image

DVM645BI GB

15

Red

Measuring Capacitance
















Figure 2-6. Measuring Capacitance

WARNING

Turn off the power to the device under test and discharge all
capacitors.

c

Turn the selector to capacitance.

d

Connect the leads as shown: insert the black and red test leads into the COM

and V

Hz input terminals respectively.

e

is not available with capacitance, all other buttons can be used.

1. Turn off the power to the device under test and discharge all capacitors.

2. Completely discharge the capacitor before measuring its capacitance value.

3. Set to the capacitance range that gives the most accurate reading or select

auto range.

4. Connect the crocodile clips to the capacitor leads or insert the capacitor leads

into the multimeter measuring socket. Always observe the correct polarity when

measuring electrolytic capacitors.

5. Read the capacitance value directly from the display. The accuracy of the

capacitance measurement can be improved by first pressing the

button

(Relative mode) in order to zero the display and automatically subtract the

residual multimeter and test lead capacitance. The Relative mode also selects

manual range.

6. Residual charge in the capacitor, or capacitors with poor insulation resistance

or poor dielectric absorption may cause measurement errors.

NOTE: A safe way to discharge a capacitor is to connect a 100k

Ω resistor across

the two capacitor leads.

Advertising