COMPONENT TEST( XX1, XX5 only)

Test Voltage: Max. 8.6Vrms (open circuit)

Test Current: Max. 11mA (shorted)

Test Frequency: Line Frequency.

Components: Capacitor, Inductor, Diode, Transistor, Zener etc.

CH2 OUTPUT(XX5 only)

Output Level: 100mV / DIV(no load); 50mV / DIV(with 50Ω load).

Bandwidth: 20Hz~20MHz(-3dB)

Calibrator: Square wave about 1 KHz, 2Vp-p±3%

OTHER SPECIFICATIONS

Power Source: 115V/230V±10%, AC 50/60Hz

Power Consumption: Approx.40 Watts.

Dimensions: 324(W) x 398(D) x 132(H)mm(12.8”x15.7”x5.2”)

Net Weight: Approx. 7.6kg

Rated Range of Use: 10 C~35 C, 10~80% RH

Limits of Operation: 10 C~50 C, 10~80% RH

Storage Environment: -30 C~70 C, 10~90% RH

Graticule Illumination: A d j u s t a b l e ( X X 1 , X X 5 o n l y )

Z-Modulation:(XX5 only)

Positive TTL signal, low level blank intensity at any intensity, high level un-
blank any intensity.

Trace Rotation: Adjustable on front panel.

°

°

°

°

°

°