EMM Labs TSD1 CD/SACD TRANSPORT User Manual

Page 15

Advertising
background image

015

Appendix A - Serial Remote Control (RS232)

© 2010 EMM Labs Inc., All Rights Reserved. EMM Labs reserves the right to amend specifications & design without notice.

TSD1 CD/SACD TRANSPORT OWNER’S MANUAL

Serial Remote Control (RS232)

The TSD1 is equipped with a 9-pin RS232 port for system remote control via a serial cable

(not provided by EMM Labs). Please use a standard RS232 cable. Do not use a null model

cable, as this will not work. RS232 communication port settings:

• 19,200 baud

• 8 bits

• 1 stop bit

• no flow control

• no parity bit

Commands to the TSD1

All commands sent to the TSD1 consist of 3 ASCII characters (all lowercase) followed by a

carraige return or <CR>. Repeating a <CR> will repeat the last command sent. Received

commands are not stored in a stack. They need to be sent in intervals of at least 50ms to

allow enough time for the TSD1 to execute a command before receiving the next one.

Command

Function

ply

Start Playback

pse

Pause Playback

stp

Stop Playback

mod

Toggles through the SACD playback layers. Only works when not playing.

rpt

Toggles through the different repeat modes

nxt

Jumps ahead a track

prv

Jumps back a track