Appendix A: Serial Remote Control (RS-232)


The DCC2 is equipped with a 9-pin RS-232 connector for system remote control via a
serial cable (not provided by EMM Labs). The cable should be non-crossed for
connections between a PC and the DCC2. The parameters and settings for this link are:

• 19,200

baud

• 8

bits

• 1 stop bit

• no flow control

• no parity bit


Commands to DCC2


All commands sent to the DCC2 consist of 3 ASCII characters followed by a <CR>.
Repeating a <CR> will repeat the last command sent. This feature can be used to adjust
the volume of the DCC2 over a wide range. Received commands are not stored in a
stack and, therefore, need to be sent in intervals of at least 30ms to allow enough time for
the DCC2 to execute a command before receiving the next one.

Char 0

Char 1

Char 2

<CR>

Char 0

>30ms



mut

Toggles mute on / off

wbw

Select wide bandwidth for digital audio playback

nbw

Select narrow bandwidth for digital audio playback

pol

Toggles polarity of all analog outputs inversed / normal

48k

Selects 48kHz base sample frequency

44k

Selects 44.1kHz base sample frequency

clk

Toggles external clock selection on / off

pst

Selects PCM input on ST glass connectors

tos

Selects PCM input on TOSLink connector

cox

Selects PCM input on coax connector

aes

Selects PCM input on AES/EBU connectors

dst

Selects DSD input on ST glass connectors

bnc

Selects DSD input on BNC connectors

rca

Selects analog input on RCA connectors

xlr

Selects analog input in XLR connectors

don

Turns front panel display on

dof

Turns front panel display off (unit keeps operating)

pon

Turns power on from standby

pof

Turns DCC2 into standby operation

vup

Moves volume up by 1 step (repeat only <CR> to move multiple steps)

vdn

Moves volume down by 1 step (repeat only <CR> to move multiple steps)