4.5 MX-2100 Sensor Replacement

Sensors – Instrument can hold at the same time:

1 – Combustible Sensor

1 – Large Sensor

and up to

2 – Small Sensors

These are smart, plug-in, precalibrated and interchangeable sensors. See section 4.6 for

ENMET

part numbers.

Turn instrument off.

C

AUTION

:

Failure to turn instrument off prior to replacing sensors may cause damage to the instruments programming.

Remove the four screws that hold the sensor comer in place and remove the cover.

Remove the sensor, by pulling it straight out.

Replace with new sensor.

N

OTE

:

Sensor can only go in one direction. Do Not force into place.

Replace the cover and screws.

Turn the instrument on and verify that the new sensor is programmed correctly for you application.

See sections 4.3 and 4.4 for calibration.

Figure 6: MX-2100 Sensor Replacement

Combustible Sensor
LEL 0 – 100% Gas

Oxygen Sensor – w/2 year life (Large Model)

OR: CO/H2S, CO2 IR, Semiconductor,

SO2, ETO, etc.

Toxic Sensor (Small Models)
Oxygen Sensor w/1 year life
(Small Model)

C

OVER

Sensors

MX-2100 Sensor Locations