4.0 Display Settings

To display the current settings of the GS-24-DF use the push button switches. See figures 1 and 2 for
location of switches.
Access the M

ENU

and S

ELECT

switches through holes in front. See figures 1 and 2.

To cycle through the display settings press:

M

ENU

switch once = Low Flow alarm setting.

M

ENU

switch twice = High Flow alarm setting.

M

ENU

switch three times = Audio alarm on or off.

M

ENU

switch four times = Raw sensor signal in millivolts.

To disable audio alarm press:

S

ELECT

switch once = Audio Alarm (horn) disabled for approximately 1 minute.

4.1 Changing Display Settings

To change the current setting of the GS-24-DF use the push button switches.

Press and hold M

ENU

switch for three seconds, display will indicate Units

Press M

ENU

switch again, once for each setting: SET LO, SET HI, Set audio or Display menu.

When Units is displayed: Press S

ELECT

switch to change value.

Press M

ENU

switch to step through the values: LPM, CCM, CFM

Press S

ELECT

switch to exit, Display steps to SET LO

When SET LO is displayed: Press S

ELECT

switch to display the value.

Press M

ENU

switch to change the value.

Press S

ELECT

switch to Exit

When SET HI is displayed: Press S

ELECT

switch to display the value.

Press M

ENU

switch to change the value.

Press S

ELECT

switch to Exit

When SET AUD is displayed: Press S

ELECT

switch to display On or Off.

Press M

ENU

switch to change

Press S

ELECT

switch to Exit

When DISPLAY is displayed: Press S

ELECT

switch to display On or Off.

Press M

ENU

switch for Flow Dsp or Go/NoGo.

Press S

ELECT

switch to Exit