Maintenance

276

FTB-7000 Series

Verifying Your OTDR

To determine the measurement range (singlemode models only):
1.
Connect the OTDR as indicated below. Other configurations are

possible, but the fiber should have several sections longer than 2 km,
with no loss greater than 8 dB and with the average attenuation not
exceeding 1 dB/km. A variable attenuator will be used to adjust the loss
in the span.

One or several non-reflective events with a nominal loss of 0.5 dB
should be present. Join a series of fiber reels between the OTDR and
the variable attenuator for a length of approximately 20 km. Join
another series of reels to complete the fiber length needed for the test.

³

Ensure that the OTDR port and connectors are correctly cleaned.

³

Make sure the fiber settings are accurate (IOR, Helix factor, and
RBS).

1 to M reels of fiber

( Add as needed )

OTDR

2 km or more

Fiber End

Measured
Fiber Event

4 km min

2 km or more

20 km

Variable attenuator

2 km or more

2 km or more

Fiber end

1 to M reels of fiber

(Add as needed)

4 km min.

Measured fiber end

Advertising