Test Results

278

FTB-700G/800 Series

Alarms/Errors

C-LOS (Client Signal Fail - Loss Of Signal)

RX: A CSF frame is received with CSF type equal to 000. The alarm is
cleared when no CSF (C-LOS) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-LOS) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).

TX: Generates a CSF frame with CSF type equal to 000.

C-FDI (Client Signal Fail - Forward Defect Indication)

RX: A CSF frame is received with CSF type equal to 001.The alarm is
cleared when no CSF (C-FDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-FDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).

TX: Generates a CSF frame with CSF type equal to 001.

C-RDI (Client Signal Fail - Remote Defect Indication)

RX: A CSF frame is received with CSF type equal to 010. The alarm is
cleared when no CSF (C-RDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-RDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).

TX: Generates a CSF frame with CSF type equal to 010.

C-DCI (Client Signal Fail - Defect Clear Indication)

TX: Generates a CSF frame with CSF type equal to 011.