Exo Terra Waterfall User Manual

Page 3

Advertising
background image

4

A. For INDOOR HOUSEHOLD USE ONLY, NOT for commercial use.

For use with FRESHWATER only.

B. Carefully examine the appliance after installation. It should not be

plugged in if there is water on parts not intended to be wet.

C. If the pump shows any sign of abnormal water leakage,

immediately unplug it from the power source.

D. Do not operate any appliance if it has a damaged cord or plug,

or if it is malfunctioning or if it is dropped or damaged in any

manner. The power cord of this appliance is a Z type attachment

and cannot be replaced; if the cord is damaged, the appliance

should be discarded. Never cut the cord.

E. To avoid the possibility of the

appliance plug or electrical socket

getting wet, position the unit to one

side of a wall mounted socket to

prevent water from dripping onto

the socket or plug. A “drip-loop”

should be arranged. The “driploop”

is that part of the cord below the

level of the socket, or the connector

if an extension cord is used, to

prevent water from traveling along

the cord and coming into contact with the socket. If the plug or

socket does get wet, DO NOT unplug the cord. Disconnect the

fuse or circuit breaker that supplies power to the appliance. Then

unplug and examine for the presence of water in the socket.

3. It is suggested that this appliance and any other submersed

appliance be equipped with a leakage circuit breaker.

4. This appliance is not intended for use by persons (including

children) with reduced physical sensory or mental capabilities,

or lack of experience or knowledge, unless they have been given

supervision or instruction concerning use of the appliance by a

person responsible for their safety. Children should be supervised

to ensure that they do not play with the appliance.

5. Always unplug an appliance from an outlet when not in use,

before putting on or taking off parts, and before cleaning. Never

yank cord to pull the plug from the outlet. Grasp the plug and pull

to disconnect.

6. Disconnect the plug of this and any other submersed appliance

before placing hands in the water.

7. The pump must be immersed in water (maximum water

temperature 35°C / 95°F). The pump must not run dry.

8. Read and observe all the important notices on the appliance.

9. Do not use this appliance for other than its intended use. The

use of attachments not recommended or sold by the appliance

manufacturer may result in a dangerous situation.

10. Do not install or store the appliance where it will be exposed to

the weather or to temperatures below freezing.

11. Do not expose the appliance under sunlight or place at low

temperature for a long period of time.

12. Make sure the appliance is securely installed before operating it.

13. If an extension cord is necessary, a cord with a proper rating

should be used. A cord rated for less amperes or watts than the

appliance rating may overheat. Care should be taken to arrange

the cord so that it will not be tripped over or pulled.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Only close adherence to these installation, electrical and

maintenance guidelines will ensure the safe and efficient use of

this appliance.

The Exo Terra

®

Waterfall is powered by the Exo Terra

®

Repti Flo 200

Circulation Pump (included). The pump is for indoor, household use

only and is designed to power a variety of appliances that require a

submersible circulating pump such as reptile fountains, terrarium

waterfalls, circulating water parts, etc. The pump is hermetically

sealed to ensure safety and a long lasting life. Since it does not

employ older technologies requiring oil cooling, it can never leak or

contaminate the area with coolant. This pump is not recommended

or designed to transport corrosive or flammable compounds or

liquids with different properties than water. The motor winding is

hermetically sealed with epoxy. This insulates against the possibility

of electric shock and seals all electrical components from water

infiltration. The motor is extremely compact and energy efficient,

while at the same time producing a continuous output flow.

ExO TERRA

®

WATERFALL INSTALLATION INSTRUCTIONS

CAUTION

• Disconnect the plug of this and any other submersed appliance

before placing hands in the water.

• The pump must not be allowed to run dry. Check the water level

periodically to ensure water level is sufficient to immerse pump

during operation. Refill water level as necessary.

1. Insert the pump into the Waterfall basin. Press down firmly on

the pump to ensure the suction cups on the bottom of pump fully

secure the pump in place. Attach the pump to the Waterfall output

tube located in the interior cavity of the rock.

2. Arrange the Waterfall in its final position in the terrarium. The

Waterfall should be placed on a flat, level surface.

3. Fill the basin with enough water to cover the pump.

4. Plug in the unit. If the unit does not start immediately, verify

that the water level is sufficient to immerse the pump during

operation. If the problem persists, see the “Trouble-shooting” and

“Maintenance” sections of this manual for further information.

WATER TREATmENT

The water should be treated with Exo Terra

®

Aquatize to remove

chlorine and heavy metals. If the water is used as drinking water by

the terrarium inhabitants, extra calcium can be added by using Exo

Terra

®

Calcium. Adding Exo Terra

®

Biotize will help to keep the water

cleaner longer, as well as promoting necessary beneficial bacteria

and reducing odors associated with decaying waste.

FLOW CONTROL

Note: water flow can be increased or decreased by adjusting

the flow control tab located on the impeller cover. To access the

impeller cover: remove the intake screen from the pump; move the

flow control tab on the impeller cover either up (decrease) or down

(increase) to adjust the water flow; replace the intake screen on

the pump. If you have trouble moving the flow control tab: simply

remove the impeller cover totally; turn the impeller cover so that the

flow control tab is in the desired position; replace the impeller cover

with the tab in the desired position; replace the intake screen.

maintenance

• Warning: To avoid injury, always unplug all appliances from the

outlet when not in use. Disconnect the plug of this pump, and any

other electrical equipment, used for the terrarium, paludarium

ENGLISH

FRANÇAIS

DEUTSCH

ESP

AÑOL

IT

ALIANO

NEDERLANDS

Advertising