- 46 -

18.5 Silencer

A

2

1

3

Key

1 fixed silencer

2 Silencer retaining clip

3 Removable silencer

• Unclip and remove the silencer (3).

• Clean the interior of the silencer with a dry cloth if necessary,

taking care not to damage the internal foam.

• Repeat the operation in reverse order to replace the silencer.

18.6 Central heating expansion vessel

2

1

Key

1 Expansion vessel

2 Expansion vessel pressure inlet

• Check the expansion vessel's supply pressure (see « Technical

Data » chapter) by means of the pressure inlet located on the

expansion vessel. Adjust the pressure if necessary.

• Following the installation of a new expansion vessel, fill and

purge the appliance or installation, if necessary.

18.7 DHW expansion vessel

1

Key

1 DHW expansion vessel

i

It is not necessary to remove the heating expansion

tank to remove the hot water expansion tank.

• Check the hot water expansion tank supply pressure (see

section “Technical data”) using the pressure tap located below

it and adjust if necessary.

• Following the installation of a new expansion vessel, fill and

purge the appliance or installation, if necessary.