12 servicing – Glow-worm Ultrapower sxi User Manual

Page 35

Advertising
background image

35

12 Servicing

12.6 Condense Trap and Siphonic Drain

The condensate trap & siphonic drain does not normally need

servicing unless material deposits exceed beyond the service

fill level, see diagram 12.14.

To clean the condense trap remove the sump and rinse with

water.

13356

BURNER

FRONT INSULATION

GASKET

SECURING

SCREW (4)

SPARK

ELECTRODE

GAS VALVE

AND FAN

BURNER

DOOR

Diagram 12.12

Diagram 12.13

15452

GAS CONTROL

VALVE

OFFSET

ADJUSTMENT

THROTTLE

ADJUSTER

Diagram 12.15

13762

SEAL (4 pieces)

BOILER MODULE

FRONT CASING

PANEL

FLEXIBLE

CONDENSATE

HOSE

CONDENSE TRAP

& SIPHONIC DRAIN

Turn

anti-clockwise

to remove

SERVICE

FILL LEVEL

Diagram 12.14

13326

12.7 Boiler Module Front Casing Panel Seal

Check

Check the condition of the seal, if worn or damaged remove

the seal and thoroughly clean the casing surface before fitting

the new seal, see diagram 12.15.
Refit the casing panel.
NOTE: Ensure the seal is fitted correctly giving an airtight

joint.

Advertising