11. Technical Data

The Lima B.11, certified in compliance with DIN-EN 13240 : 2005-10/1 : 2008-06
and Art. 15 a B-VG (Austria)
, can only be operated when the fire box is closed; more
than one device can be connected to the chimney. VKF-No.: 22674;

The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2

Combustion Values

Wood

Briquette

Nominal Thermal Output

6

6

kW

CO content at 13% O2

80

79

mg/m³

Efficiency

13

26

%

CO content at 13% O2

1104

882

mg/m³

Waste Gas Mass Flow Rate

5,5

5,5

g/s

Waste Gas Outlet Temp.

320

320

˚C

Min. Supply Pressure at Nominal Thermal Output

12

12

Pa

Depending on the insulation of the building, the nominal thermal output of 6 kW indi-
cated on 20 - 80 m² (subject to change).

Dimensions:

Height

Width

Depth

Stove

121 cm

48 cm

48 cm

Fire box

43 cm

28 cm

30 cm

Weight (ceramic / soapstone):

178/214 kg

Flue pipe diameter:

15 cm

Pipe diameter of Hase ventilation system*

10 cm

* For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed

Front view

Side view

Top view

Dimensions in cm

Connection area for the
inst. of Hase air system
below

Stove‘s angle of rotation:
180° · Can be stopped in
place and locked right/left in
15° gradients. Observe safety
distances to combustible or
flammable materials!

Stove height: 121

Height for top installation: 113

24

Ш 35

6,5

Ш 48

Height for the inst. of Hase air

system: 9