Assembly to the fused side of the Secondary Pump wiring using splice (0211936). Connect the non-fused wire

from the Secondary Pump to the negative terminal of the vehicle battery using the Black wire supplied in the

kit.

Sample System and Tubing:

Ref. Schematic Drawing 102317: Attach Boom Assembly (100001-2) to the vehicle front centered on the bumper

with 2 holders 0413599. Adjust the funnel height to be one inch above the ground with the vehicle fully loaded.

Route and connect Sample Line Tubing (8301846) between boom manifold outlet and Secondary Pump inlet.

Route and connect Sample Line Tubing between the Secondary Pump outlet the By Pass Valve inlet.

Route and connect Sample Line Tubing from the By Pass Vale exhaust port to the outside of the vehicle (typically

through the floor).

Route and connect Instrument Sample Line Tubing from the By Pass Vale Instrument Port to the Instrument loca-

tion. Attach the proper connector for either the DP4 or DP-IR.

Completing installation: Use as many Tie Wraps (8300319) as needed to tie all wires and tubing into a bundle.

Tie gently to prevent tubing restriction (Don’t pinch the tubing). Adhesive Clamps (0211942) are used for final

positioning. Alcohol or another cleaning agent must be used to clean each area where the clamp is to be placed.

NOTE: KEEP WIRES AND TUBING AWAY FROM MOVING PARTS AND HOT SURFACES.