Heath Consultants Sure-Lock All Pro User Manual

Page 26

Advertising
background image

23

Two coupler clamps (see USING DUAL COUPLER CLAMPS, page 24) can
also be used in Dual Jacking.

(Correct - Grounding Application)

(Incorrect - Grounding Application)

Figure 2-6

Using the Coupler Clamp

Another direct means of energizing the conductor is with a coupler clamp. This
device can be used with the transmitter to apply the signal to the conductor, or

conductors when they are selectively energized at the transmitter location. When
it can be used, the coupler clamp is a very accurate means for tracing and identi-

**NOTE**

THE TRANSMITTER PRIOR TO ATTACHING THE DIRECT CONNEC-
TIONS (TWO GROUNDING CABLES) MUST BE SET IN THE ALL OUT-
PUT FREQUENCY MODE SO THAT THE OPERATOR WILL BE ABLE TO
SWITCH BACK AND FORTH BETWEEN THE 8.1 AND 81 kHz RANGES/
FREQUENCIES.

Advertising